  Specifications  
 
Design Loads
               
 
Dead Load:
Self weight of slab
Landing superimposed dead load = 30PSF (Topping & Finish).
Live Load 100 PSF      
  Concrete:

Minimum compressive strength of 6000 psi at 28 days.

All concrete materials, batching and workmanship shall conform to the following:

  • ACI 301: Specifications for structural concrete buildings.
  • ACI 318: Building code requirements for reinforced concrete.
  • ASTM C94: Ready mix concrete
Reinforcement Steel:
  • Deformed high strength billet steel; ASTM a615; Grade 60 KSL
  • Reinforcing Steel shall be detailed, fabricated, placed and supported to conform with the ACI detailing manual: ACI SP-66
 
  Concrete Cover to Reinforcing Steel:


Concrete Coverage: Depending on application varies from
1" - 1 1/2"

Shop Drawings:

All units shall show the following:

  • Dimensions necessary for proper fabrication.
  • Reinforcing steel, size, grades, locations
  • Inserts, accessories and handling methods
  • Calculations for reinforcing: Supple mentally supplied
 
  The Details (click on image to enlarge)      
       