THE DETAILS

Steel Angles On Concrete Walls


W / Monolithic Switch Back Stairs


Switch Back On Masonry Structure With Precast Ledger

Specifications


Design Loads
Dead Load:
Self weight of slab Landing superimposed dead load = 30PSF (Topping & Finish).
Live 1000 PSF Reinforcement Steel:

  • Deformed high strength billet steel; ASTM a615; Grade 60 KSL
  • Reinforcing Steel shall be detailed, fabricated, placed and supported to conform with the ACI detailing manual: ACI SP-66

Concrete: Minimum compressive strength of 6000 psi at 28 days. All concrete materials, batching and workmanship shall conform to the following:

  • ACI 301: Specifications for structural concrete buildings.
  • ACI 318: Building code requirements for reinforced concrete.
  • ASTM C94: Ready mix concrete

Concrete Cover to Reinforcing Steel: Concrete Coverage: Depending on application varies from 1" - 1 1/2"
Shop Drawings: All units shall show the following:

  • Dimensions necessary for proper fabrication.
  • Reinforcing steel, size, grades, locations
  • Inserts, accessories and handling methods
  • Calculations for reinforcing: Supple mentally supplied
© 2009 Durlach Industries Inc.